7
GB
Safety cutoff
The sauna heater is equipped with a temperature
limiter for security.
In case of a malfunction this temperature limiter
cuts off all 3 phases by safety reasons.
Once the temperature limiter has cut off the
current, he must be reset mechanically.
Attention:
Cut off the sauna heater from the mains at
first.
Loosen the securtiy screw from the wall holder
of the heater and take the heater off the holder.
Then open the lid of the terminal box. The
temperature limiter is mounted in the left lower
corner (fig.12).
Press the 3 locking pins of the connecting plug
back to the rear side of the housing until you feel
a switching point.
Close the terminal box again and restore the
sauna heater in the wall holder.
Secure the heater with the security screw.
In case the temperature limiter should cut off
again immediately after taking into operation, the
sauna heater has to be checked by a specialist.
Instructions Leakage current
For the installation of sauna heaters, please pay
attention to the DIN VDE 0100 part 703 !
This standard makes the following statement valid
in your newest expenditure, since February 2006,
paragraph 703.412.05;
Quotation:
The additional must be planned for all electric
circuits of the Sauna by one or more fault current
protection device (RCDs) with a calculation
difference stream not more largely than 30 mA,
excluded of it is Saunaheating.
The EN 60335-1 DIN VDE 0700 part 1 of January 2001
states the following in paragraph 13; quote:
The leakage current may not exceed the following
values during operation:
- for stationary heaters of protection class I
0,75 mA; or 0,75 mA each kW input of the appliance,
depending on the higher value, at a maximum value
of 5 mA.
If the appliance is equipped with a protective device
for leakage current (ELCB), please pay attention to
the fact that no other electrical units will be
protected by this ELCB.
Under current manufacturing methods, it is not yet
possible to produce tubular heating elements for
sauna heaters which do not attract moisture on
each end from the surrounding air.
Therefore, should the ELCB be triggered during
start-up, the electrical installation must be checked.
It is also possible that moisture from the
surrounding air has been concentrated in the
magnesium-oxide filling in the heating elements
during transport or storage and is now causing
the ELCB to be triggered.
In this case, the oven must be heated up under
supervision of an expert, during which the PE
conductor is not connected. After about 10 minutes,
when moisture has evaporated from the heating
elements , the oven must be reconnected to the PE
conductor!
If the sauna heater is not in use for a significant
period of time, we recommend running it every 6
weeks, so as to avoid moisture concentrating in
the heating elements.
Installation of the sauna heater and control unit
may be undertaken only by an authorized
electrician. Without documentation of such
installation, a warranty is fundamentally invalid.
Technical data
Voltage: 400 V AC 3N, 50 Hz
Power intake: 6.0, 7.5, kW, depending
upon model
Height: 730 mm when mounted 180 mm
above floor level
Width: 420 mm, depth: 360 mm
Stone capacity: 15 kg
Discharge current: max. 0.75 mA per kW
of heating output
Sauna heater for family saunas
Temperature limiter for security
3 locking pins behind
connecting plug
Abb. 12